Overview
ATEN’s Basic PDU family is extended with 1U members containing 18 outlets and available in IEC or NEMA socket configurations. The compact aluminum housing gives a sleek, yet robust look while minimizing installation space for work space efficiency. Thanks to the built-in surge protection module, the IT devices connected to the PDU are well-protected from sudden surges in electricity; plus, the equipment downtime is reduced as a result of the overcurrent protection design. The Basic PDUs are tailored made for individuals who are in need of industrial-grade, easy-to-deploy power distribution unit in data centers, server rooms, and network wiring closets.
Features
Diagram
Specifications
| Function | PE0218SA | PE0218SB | PE0218SG |
| Electrical | |||
| Nominal Input Voltage | 100-120 VAC | 100-240 VAC | 100-240 VAC |
| Maximum Input Current | 20A Max (UL de-rated 16A Max) |
20A Max (UL de-rated 16A Max) |
16A Max |
| Input Frequency | 50-60 Hz | 50-60 Hz | 50-60 Hz |
| Input Connection | For A Plug: NEMA L5-20P For A2 Plug: NEMA 5-20P |
NEMA L6-20P | IEC-320 C20 |
| Input Power | 2400VA(Max); 1920VA(UL de-rated) |
4800VA(Max); 3840VA(UL de-rated) |
3840VA(Max) |
| Outlet Type | (18) NEMA 5-20R | (18) IEC 320 C13 | (17) IEC 320 C13,(1) IEC 320 C19 |
| Maximum Output Current (Outlet) | 20A Max (UL de-rated 16A Max) |
15A Max (UL de-rated 12A Max) |
C13:10A Max C19:16A Max |
| Maximum Output Current (Bank) | 20A Max (UL de-rated 16A Max) |
20A Max (UL de-rated 16A Max) |
16A Max |
| Maximum Output Current (Total) | 20A Max (UL de-rated 16A Max) |
20A Max (UL de-rated 16A Max) |
16A Max |
| OPD(Overcurrent Protection Device) | Yes | Yes | Yes |
| Physical Properties | |||
| Dimensions (L x W x H) | 48.20 x 4.44 x 8.85 cm (18.98 x 1.75 x 3.48 in.) |
48.20 x 4.44 x 8.85 cm (18.98 x 1.75 x 3.48 in.) |
48.20 x 4.44 x 8.85 cm (18.98 x 1.75 x 3.48 in.) |
| Weight | 1.26 kg ( 2.78 lb ) | 1.26 kg ( 2.78 lb ) | 1.26 kg ( 2.78 lb ) |
| Power Cord Length | 10ft(12#) | 10ft(12#) | 10ft(3×1.5mm2) |
| Environmental | |||
| Temperature (Operating / Storage) | 0 – 40℃ / -20 – 60℃ | 0 – 40℃ / -20 – 60℃ | 0 – 40℃ / -20 – 60℃ |
| Elevation (Operating / Storage) | 3000m | 3000m | 3000m |
| Compliance | |||
| EMC Verification | FCC Class A | FCC Class A | CE Class A |
| Safety Verification | By Request | By Request | CE,LVD |
| Note | For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format. | ||
Select at least 2 products
to compare